Input data

CSV File Name: cbat_dist characteristic of candidate battery units

Columns:

bus

icost

ocost

scost

ec

ed

emax

emin

eini

pmax

pmin

qmax

qmin

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh] (default = 0)

scost: Start-up cost [$] (default = 0)

ec: Charging mode efficiency

ed: Discharging mode efficiency

emax: Maximum limit of stored energy for each battery unit [kWh]

emin: Minimum limit of stored energy for each battery unit [kWh]

pmax: Maximum limit of active power production for each battery unit [kW]

pmin: Minimum limit of active power production for each battery unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: cblt_dist Characteristic of different cables

Columns:

crs

r0

i0

r1

x1

z1

i1

r2

x2

z2

i2

r3

x3

z3

i3

r4

x4

z4

i4

r5

x5

z5

i5

r6

x6

z6

i6

r7

x7

z7

i7

csr: Cross-section [mm2]

r0: Resistance (2 cables, DC) [mΩ/m]

i0: Rated current (2 cables, DC) [A]

r1: Resistance (2 cables, single-phase DC, enclosed in conduit or trunking) [mΩ/m]

x1: Reactance (2 cables, single-phase DC, enclosed in conduit or trunking) [mΩ/m]

z1: Impedance (2 cables, single-phase DC, enclosed in conduit or trunking) [mΩ/m]

i1: Rated current (2 cables, single-phase DC, enclosed in conduit or trunking) [A]

r2: Resistance (2 cables, single-phase DC, cables touching) [mΩ/m]

x2: Reactance (2 cables, single-phase DC, cables touching) [mΩ/m]

z2: Impedance (2 cables, single-phase DC, cables touching) [mΩ/m]

i2: Rated current (2 cables, single-phase DC, cables touching) [A]

r3: Resistance (2 cables, single-phase AC, cables spaced) [mΩ/m]

x3: Reactance (2 cables, single-phase AC, cables spaced) [mΩ/m]

z3: Impedance (2 cables, single-phase AC, cables spaced) [mΩ/m]

i3: Rated current (2 cables, single-phase AC, cables spaced) [A]

r4: Resistance (3 or 4 cables, three-phase AC, enclosed in conduit or trunking) [mΩ/m]

x4: Reactance (3 or 4 cables, three-phase AC, enclosed in conduit or trunking) [mΩ/m]

z4: Impedance (3 or 4 cables, three-phase AC, enclosed in conduit or trunking) [mΩ/m]

i4: Rated current (3 or 4 cables, three-phase AC, enclosed in conduit or trunking) [A]

r5: Resistance (3 or 4 cables, three-phase AC, trefoil) [mΩ/m]

x5: Reactance (3 or 4 cables, three-phase AC, trefoil) [mΩ/m]

z5: Impedance (3 or 4 cables, three-phase AC, trefoil) [mΩ/m]

i5: Rated current (3 or 4 cables, three-phase AC, trefoil) [A]

r6: Resistance (3 or 4 cables, three-phase AC, cables touching, flat) [mΩ/m]

x6: Reactance (3 or 4 cables, three-phase AC, cables touching, flat) [mΩ/m]

z6: Impedance (3 or 4 cables, three-phase AC, cables touching, flat) [mΩ/m]

i6: Rated current (3 or 4 cables, three-phase AC, cables touching, flat) [A]

r7: Resistance (3 or 4 cables, three-phase AC, cables spaced, flat) [mΩ/m]

x7: Reactance (3 or 4 cables, three-phase AC, cables spaced, flat) [mΩ/m]

z7: Impedance (3 or 4 cables, three-phase AC, cables spaced, flat) [mΩ/m]

i7: Rated current (3 or 4 cables, three-phase AC, cables spaced, flat) [A]

CSV File Name: cgen_dist Characteristic of candidate dispatchable units

Columns:

bus

icost

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh]

scost: Start-up cost [$]

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: clin_dist Characteristic of candidate lines

Columns:

from

to

ini

res

rea

icost

smax

pmax

qmax

from: Sending bus

to: Receiving bus

ini: Initial status

res: Resistance [pu]

rea: Reactance [pu]

icost: Annualised capital cost [$]

smax: Maximum limit of apparent power [kVA]

pmax: Inner approximation for maximum active power [kW]

qmax: Inner approximation for maximum active power [kVAr]

CSV File Name: csol_dist Characteristic of candidate solar units

Columns:

bus

icost

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh]

scost: Start-up cost [$] (default: 0)

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: csol_dist Characteristic of candidate solar units

Columns:

bus

icost

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh]

scost: Start-up cost [$] (default: 0)

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kW]

qmin: Minimum limit of reactive power production for each battery unit [kW]

CSV File Name: cwin_dist Characteristic of candidate wind units Columns

bus

icost

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh]

scost: Start-up cost [$] (default: 0)

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: dtim_dist Duration time of each representative day obtained by clustering techniques

Columns:

dt

dt: Duration time of each representative day obtained by clustering techniques [h]

CSV File Name: egen_dist Characteristic of existing dispatchable units

Columns:

bus

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

ocost: Operation cost [$/kWh]

scost: Start-up cost [$]

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: elin_dist Characteristic of existing lines

Columns:

from

to

ini

res

rea

sus

smax

pmax

qmax

from: Sending bus

to: Receiving bus

ini: Initial status

res: Resistance [pu]

rea: Reactance [pu]

sus: Susceptance [pu]

smax: Maximum limit of apparent power [kVA]

pmax: Inner approximation for maximum active power [kW]

qmax: Inner approximation for maximum active power [kVAr]

CSV File Name: esol_dist Characteristic of existing solar units

Columns:

bus

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

icost: Annualised investment cost [$/year]

ocost: Operation cost [$/kWh]

scost: Start-up cost [$] (default: 0)

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: cwin_dist Characteristic of existing wind units

Columns:

bus

ocost

scost

pmin

pmax

qmin

qmax

bus: Bus number

ocost: Operation cost [$/kWh]

scost: Start-up cost [$] (default: 0)

pmax: Maximum limit of active power production for each unit [kW]

pmin: Minimum limit of active power production for each unit [kW]

qmax: Maximum limit of reactive power production for each battery unit [kVAr]

qmin: Minimum limit of reactive power production for each battery unit [kVAr]

CSV File Name: geol_dist Geographical location of load points for feeder routing

Columns:

Longtitude

Latitude

Longtitude: Longitude of a load point

Latitude: Latitude of a load point

Note: The first column represents the index of each load point and it starts from 0

Worksheet File Name: mgpc_dist Characteristic of load points

Sheets:

Load Point: longitude, latitude, hourly participation factors of load points

Load Level: Total load levels at each hour of the scheduling horizon

Note: To construct the load profile, the following tool from NREL can be used:

Microgrid Load and LCOE Modelling Results, available online: https://data.nrel.gov/submissions/79

CSV File Name: pdem_dist Hourly participation factors of load points (active power)

Note: The first row represents the index of load points and each column represents the hourly participation factors for 24 hours of a single day.

CSV File Name: prep_dist Hourly total active load levels of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total active load levels for 24 hours of each representative day in kW.

CSV File Name: psol_dist Hourly total available solar active power of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total available solar power for 24 hours of each representative day in kW.

CSV File Name: pwin_dist Hourly total available wind active power of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total available wind power for 24 hours of each representative day in kW.

CSV File Name: qdem_dist Hourly participation factors of load points (reactive power)

Note: The first row represents the index of load points and each column represents the hourly participation factors for 24 hours of a single day.

CSV File Name: qrep_dist Hourly total reactive load levels of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total reactive load levels for 24 hours of each representative day in kW.

CSV File Name: qsol_dist Hourly total available solar reactive power of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total available solar power for 24 hours of each representative day in kW.

CSV File Name: qwin_dist Hourly total available wind active power of the microgrid

Note: The first row represents the index of all representative days and each column represent the hourly total available wind power for 24 hours of each representative day in kW.

CSV File Name: rou_dist Distance between pairs of connected buses

Columns:

from

to

distance

from: Sending bus

to: Receving bus

distance: Distance between a pair of connected buses